Cutting type
Sample chamber dimensions: 200 × 296 × 70 mm
Light wavelength: 365 nm / 395 nm
Ultraviolet irradiance: 10–100 mW/cm² (100-level adjustment)
Test force: See the product details page.
Loading method: Automatic
Maximum specimen height: 110–200 mm
Turret: Automatic
Distance from the indenter center to the machine wall: 130 mm
XY coordinate test table: 100×100 mm
Dimensions: 500×330×660 mm
Digital Rockwell Hardness Tester
Test force: 60 kgf (588.4 N), 100 kgf (980.7 N), 150 kgf (1471 N)
Loading method: electric
Maximum specimen height: 230 mm (protective sleeve must be removed; remove the first 140 mm before removal).
Distance from the center of the pressure head to the machine wall: 165 mm
Data Output: Built-in Printer, RS232 Interface
Screen specifications: 8-inch touchscreen
Test force: 9.807 N – 490.3 N (8 levels)
Loading method: Automatic
Maximum specimen height: 110 mm – 200 mm
Turret: Automatic
Built-in printer: Yes
Distance from the indenter center to the machine wall: 130 mm
Automatic worktable dimensions: 312 × 225 (mm)
Test force: See the product details page.
Loading method: Automatic
Maximum specimen height: 110 mm – 200 mm
Turret: Automatic
Built-in printer: Yes
Distance from the indenter center to the machine wall: 130 mm
Automatic worktable dimensions: 312 × 225 (mm)
Surface Rockwell hardness tester
Test forces: 147.1 N (15 kgf), 294.2 N (30 kgf), 441.3 N (45 kgf)
Loading method: weights
Maximum specimen height: 100 mm with the lead screw guard installed; 170 mm without the lead screw guard.
Distance from the indentation center to the machine wall: 128 mm
Electric Height-Adjustable Rockwell Hardness Tester
Total test force: 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf)
Loading method: electric
Maximum specimen height: 400 mm
Distance from the indenter center to the machine wall: 160 mm
Digital Display Height-Adjustable Rockwell Hardness Tester
Total test force: 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf)
Loading modes: automatic loading, load holding, and unloading
Maximum specimen height: 400 mm
Distance from the indenter center to the machine wall: 160 mm
Total test force: 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf)
Loading method: weights
Maximum specimen height: 400 mm
Distance from the indenter center to the machine wall: 160 mm
Metallographic Sample Polishing Machine
Throwing disc diameter: ∮203mm
Rotational speed: 1400 r/min
Input Power: 360W
Metallographic Sample Polishing Machine (Dual-Use Desktop and Vertical Model)
Throwing disc diameter: ∮203mm
Rotational speed: 1400 r/min
Input power: 360 W
Metallographic Sample Polishing Machine
Throwing disc diameter: ∮203mm
Rotational speed: 1400 r/min
Input Power: 180W
Metallographic Sample Polishing Machine
Throwing disc diameter: ∮203mm
Rotational speed: 1400 r/min (customizable to 900 r/min)
Input Power: 360W
Worktable diameter: Φ300 mm
Specimen clamping diameter: φ20–φ50
Input power: 1300 W
Grinding disc diameter: φ350mm
Grinding disc speed: 1400 r/min, 2800 r/min (two-speed fixed)
Input voltage: AC 380 V, 50 Hz (three-phase five-wire system)
Input power: 2 kW
Abrasive Belt Grinding Machine
Abrasive belt specifications: width 100 mm, circumference 920 mm
Number of sanding belts: 1
Rotational speed: 1400 rpm
Surface speed: 768 meters per minute
Input power: 550W
Abrasive Belt Grinding Machine
Abrasive belt specifications: width 100 mm, circumference 920 mm
Number of sanding belts: 2
Rotational speed: 1400 rpm
Surface speed: 768 meters per minute
Input power: 550W
Automatic Metallographic Grinding and Polishing Machine
Pressurization method: central pressurization
Speed control methods: two-speed fixed-speed and stepless variable-speed
Grinding and polishing head speed: 50–100 r/min (stepless speed regulation)
Input Power: 700W
Automatic Metallographic Sample Grinding and Polishing Machine
Grinding and polishing pad diameter: φ250 mm (customizable to φ203 mm or φ300 mm)
Pressurization method: single-point pressurization
Grinding and polishing pad speed control methods: two-speed fixed-speed and stepless speed regulation.
Grinding and polishing head speed: 50–150 r/min (stepless speed regulation)
Number of samples to be prepared: 6 (standard configuration)
Input power: 1.1 kW
Automatic Metallographic Sample Grinding and Polishing Machine
Grinding and polishing pad diameter: φ250 mm (customizable to φ203 mm or φ300 mm)
Pressurization method: single-point pressurization
Grinding and polishing pad speed control methods: two-speed fixed-speed and stepless speed regulation.
Grinding and polishing head speed: 50–150 r/min (stepless speed regulation)
Number of samples to be prepared: 4 (standard configuration)
Input power: 1.1 kW
Automatic Metallographic Sample Grinding and Polishing Machine
Grinding and polishing pad diameter: φ250 mm (customizable to φ203 mm)
Pressurization method: single-point pressurization
Grinding and polishing pad speed control methods: two-speed fixed-speed and stepless speed regulation.
Grinding and polishing head speed: 50–150 r/min (stepless speed regulation)
Number of samples to be prepared: 4 (standard configuration)
Input power: 1.1 kW
Automatic Metallographic Sample Grinding and Polishing Machine
Grinding and polishing pad diameter: φ250 mm (customizable to φ203 mm)
Pressurization method: single-point pressurization
Grinding and polishing pad speed control methods: two-speed fixed-speed and stepless speed regulation.
Grinding and polishing head speed: 50–150 r/min (stepless speed regulation)
Number of samples to be prepared: 6 (standard configuration)
Input power: 1.1 kW
Fixture diameter: φ30mm
Number of test specimens to be prepared: 1–3
Polishing pad rotational speed: 50 r/min
Force applied to each specimen: 0–40 N
Grinding and Polishing Machine Circulating Water Tank
Water tank capacity: 60L
Filter Cartridge: ● I ● II ● III ○ 0.1μm
Low-speed precision cutting machine
Gravity-based speed regulation
Automatic shutdown upon completion of cutting
Cutting disc diameter: Φ100×0.5×20mm
Power: 80W
Integrated Lithofacies Polishing Machine
Left-side cutting chamber, right-side grinding chamber
Cutting disc diameter: Φ250×Φ32×2mm (customizable to Φ250×Φ25.4×2mm)
Grinding disc diameter: Φ175mm
Grinding disc speed: 0–3000 r/min
Cutting worktable stroke/movement type: 200 mm/manual
Grinding table travel/movement type: 10 mm/manual (accuracy: 0.01 mm)
Metallographic Cutting Machine
Test force: Maximum cutting capacity: Φ110 mm
Maximum cutting capacity: Φ110mm
Cutting disc specifications: Φ350×2.5×32mm
Cutting power: 4 kW
Rotational Speed: 2,300 rpm
Workbench dimensions: 760*620*450 mm
Input power: 380V/50HZ
Metallographic Cutting Machine
Maximum cutting capacity: Φ65mm
Cutting disc specifications: Φ250×2×32mm
Cutting power: 1.5 kW
Rotational speed: 2,800 rpm
Input power: 380V/50HZ
Metallographic Cutting Machine
Maximum cutting capacity: Φ65mm
Cutting disc specifications: Φ250×2×32mm
Cutting power: 1.5 kW
Rotational speed: 2,800 rpm
Input power: 380V/50HZ
Automatic Metallographic Cutting Machine
Maximum cutting capacity: Φ110 mm
Cutting methods: chopping deceleration cutting, pushing deceleration cutting
Chop-style pulse cutting, push-style pulse cutting
Maximum Y-axis travel: 240 mm
Cutting power: 5 kW
Rotational speed: 2,300 rpm
Input power: Three-phase 380V/50Hz
Metallographic Cutting Machine
Maximum cutting capacity: Φ60mm
Spindle speed: 2,800 rpm
Cutting disc specifications: 250×1.5×25.4 mm
Cutting power: 2.2 kW
Input power supply: Three-phase four-wire (380 V, 50 Hz)
Room-temperature curing, strong penetration, stable performance, high hardness, and multiple curing time options.
Lower operating costs
Metallographic Polishing Lubricant
Capacity: 1L
Non-toxic and harmless, gentle on the skin, and environmentally friendly.
Protect the test specimen from burning.
Cooling, lubrication, and rust prevention
High-Efficiency Diamond Polishing Spray
Particle size: 20, 14, 10, 7, 5, 3.5, 2.5, 1.5, 1, 0.5, 0.25 μm
Diamond Suspension Polishing Fluid
Capacity: 500 ml / 1000 ml
Higher particle size concentration
A more stable suspension system
High grinding rate and removal rate
Volatile Organic Compound-free
Digital Rockwell Hardness Tester
Initial test force: 10 kgf
Total test force: 60/100/150 (kgf)
Loading method: electric
Maximum specimen height: 100 mm or 170 mm
Distance from the indenter center to the machine wall: 128 mm
Electric Rockwell Hardness Tester
Initial test force: 10 kgf
Total test force: 60/100/150 (kgf)
Loading method: electric
Indicator scale: C: 0–100; B: 30–130
Maximum specimen height: 100 mm or 170 mm
Distance from the indenter center to the machine wall: 128 mm
Semi-automatic digital Vickers hardness tester
Test force: See the product details page.
Loading method: Automatic
Magnification of the reading eyepiece: 200×, 400×
Focus mode: Manual
Hardness reading: automatic measurement by computer
Maximum specimen height: 110 mm – 200 mm
Distance from the indenter center to the machine wall: 130 mm
Automatic worktable dimensions: 312 × 225 (mm)
Fully Automatic Digital Vickers Hardness Tester
Test force: See the product details page.
Loading method: Automatic
Focusing mode: manual or automatic
Hardness reading: automatic measurement by computer
Maximum specimen height: 110 mm – 200 mm
Distance from the indenter center to the machine wall: 130 mm
Automatic worktable dimensions: 312 × 225 (mm)
Digital Brinell Hardness Tester
Test force: 62.5 kgf – 3000 kgf (6 levels)
Loading method: weights
Reading lens magnification: 20×
Objective magnification: 1×
Maximum specimen height: 320 mm
Distance from the indenter center to the machine wall: 175 mm
Digital Brinell Hardness Tester
Test force: 62.5 kgf – 3000 kgf (10 levels)
Loading method: electric
Turret configuration: automatic five-station
Reading lens magnification: 20×
Objective magnification: 1×, 2×
Maximum specimen height: 280 mm
Distance from the indenter center to the machine wall: 175 mm
MP-1 Metallographic Sample Pre-Polishing Machine
Grinding and polishing disc diameter: φ203mm
Polishing pad rotational speed: 450 rpm (or customized upon request)
Input power: 370W
Manual Grinding and Polishing Machine
Diameter of grinding and polishing disc: φ203mm
Grinding and polishing disc speed: 0-1400r/min (stepless speed change)
Grinding and polishing disc steering: adjustable clockwise and counterclockwise
Manual Grinding and Polishing Machine
Grinding and polishing pad diameters: φ203 mm / φ250 mm / φ300 mm
The polishing and buffing pads have the following speed ranges: 0–1400 r/min (φ203 mm, stepless speed control); 0–1000 r/min (φ250 mm/300 mm, stepless speed control).
Polishing pad rotation: adjustable clockwise and counterclockwise
Fixed speeds: four-level fixed-speed settings of 150/300/600/1000 r/min
Manual Grinding and Polishing Machine
Grinding and polishing disc diameter: φ203 mm
The polishing and buffing discs operate at the following speeds: 450 r/min for the left disc and 600 r/min for the right disc (or customized according to customer requirements).
Manual Grinding and Polishing Machine
Grinding and polishing disc diameter: φ203 mm
Polishing pad speed: 0–1400 r/min (stepless variable speed)
Polishing pad rotation: adjustable clockwise and counterclockwise
Manual Grinding and Polishing Machine
Grinding and polishing pad diameter: φ203 mm / 250 mm
Polishing pad speed: 0–1400 r/min (φ203 mm, stepless speed regulation); 0–1000 r/min (φ250 mm, stepless speed regulation).
Fixed speeds: four-level fixed-speed settings of 150/300/600/1000 r/min
Polishing pad rotation: adjustable clockwise and counterclockwise
Manual Grinding and Polishing Machine
Grinding and polishing pad diameter: φ203 mm / 250 mm
Polishing pad speed: 0–1400 r/min (φ203 mm, stepless speed regulation); 0–1000 r/min (φ250 mm, stepless speed regulation).
Fixed speeds: four-level fixed-speed settings of 150/300/600/1000 r/min
Polishing pad rotation: adjustable clockwise and counterclockwise
Diameter: φ100/φ150/φ200 (mm)
High hardness, high cutting efficiency, wide applicability, and long service life.
Metallographic Sample Cutting Disc
Diameter: φ200/φ250/φ300/φ350/φ400/φ450/φ508/φ610 (mm)
Sharp cutting, smooth cuts, heat dissipation, and burn prevention.
Touchscreen Electronic Brinell Hardness Tester
Test force: 62.5 kgf – 3000 kgf (10 levels)
Loading method: electric
Reading lens magnification: 20×
Maximum specimen height: 210 mm
Distance from the indenter center to the machine wall: 150 mm
Hardness value reading: automatic calculation and display of entered values
Environmentally Friendly Cutting Coolant Lubricant
Capacity: 1L, 2L, 4L, 6L, 10L
Non-toxic and harmless, gentle on the skin, and environmentally friendly.
Protect the test specimen from burning.
Cooling, lubrication, and rust prevention .
Manual Grinding and Polishing Machine
Grinding and polishing disc diameter: φ203 mm
Polishing pad speed: 0–1400 r/min (stepless speed control via knob)
Fixed speeds: 150/300/700/1400—four fixed-speed settings
Polishing pad rotation: adjustable clockwise and counterclockwise
Model pressure detection: 0–60 N
Manual Rockwell Hardness Tester
Initial test force: 10 kgf
Total test force: 60/100/150 (kgf)
Loading method: weights
Indicator scale: C: 0–100; B: 30–130
Maximum specimen height: 100 mm or 170 mm
Distance from the indenter center to the machine wall: 128 mm
Metallographic Sample Cutting Machine
Maximum cutting capacity: 100 mm
Cutting disc specifications: φ350×2.5×32 (mm)
Spindle travel: 145 mm
Worktable travel: 300 mm
Worktable dimensions: 330 × 280 mm
Cutting chamber material: stainless steel
Metallographic Sample Cutting Machine
Maximum cutting capacity: 100 mm
Cutting disc specifications: Φ350×2.5×32(mm)
Cutting machine power: 3kW
The two turntables can be controlled independently and operate in both manual and automatic modes.
Grinding and polishing head speed: 0–150 rpm
Central pressurization, single-point pressurization
Adjustable-height clamp
Three operating status indicator lights
Electric Lifting Grinding and Polishing Head
Dual-button control for raising and lowering the grinding/polishing head—safer operation.
3.1 kW high-power motor
Standard configuration includes a Φ30mm chuck; other specifications are available upon request.
Semi-automatic digital Vickers hardness tester
Test force: 10 gf – 1000 gf (8 levels)
Load control: Automatic
Magnification of the reading eyepiece: 100×, 400×
Turret: Automatic
Maximum specimen height: 105 mm
Distance from the indentation center to the machine wall: 110 mm
XY coordinate test table: 100 × 100 (mm)
Test force: See the product details page.
Load control: Automatic
Magnification of the reading eyepiece: 100×, 400×
Maximum specimen height: 110 mm
Distance from the indentation center to the machine wall: 110 mm
XY coordinate test table: 100 × 100 (mm)
Test force: 10 gf – 1000 gf (10 levels)
Load control: Automatic
Magnification of the reading eyepiece: 100×, 400×
Turret: Automatic
Built-in printer: Yes
Maximum specimen height: 110 mm
Distance from the indentation center to the machine wall: 110 mm
XY coordinate test table: 100 × 100 (mm)
Maximum vacuum: -85 kPa
Vacuum chamber dimensions: φ260 × 125 mm
Tray rotation speed: 5 rpm
Universal Irrigation Device
Specimen pressing diameters: three specifications—φ22, φ30, and φ45.
(One standard configuration; select when ordering)
Temperature control range: room temperature to -200°C
Timing range: 0–890 s
Total machine power: ≤800 W
Cooling method: Natural cooling
Specimen pressing diameters: three specifications—φ22, φ30, and φ45.
(One standard configuration; select when ordering)
Heating temperature range: 100–200°C
Cooling temperature range: 20–90°C
Holding pressure time range: 0–999 s
Heating power: 450–1000 W
Cooling method: Water-cooled
Specimen pressing diameter:
Imperial units: 1 inch, 1.25 inches, 1.5 inches, 2 inches
Metric 25, 30, 40, 50 mm
Number of sample preparation stations: Single station
Pressurization method: Pneumatic (0.6 MPa, 500 kgf)
Heating temperature: 90°C–200°C
Cooling method: Water-cooled
Specimen pressing diameter:
Imperial units: 1 inch, 1.25 inches, 1.5 inches, 2 inches
Metric 25, 30, 40, 50 mm
Number of sample preparation stations: Single station
Pressurization method: electric hydraulic
Heating temperature: 90°C–200°C
Cooling method: Water-cooled
Specimen pressing diameter:
Imperial units: 1 inch, 1.25 inches, 1.5 inches, 2 inches
Metric 25, 30, 40, 50 mm
Number of sample preparation stations: dual-station
Pressurization method: Pneumatic (0.6 MPa, 500 kgf)
Heating temperature: 90°C–200°C
Cooling method: Water-cooled
Automatic Metallographic Sample Cutting Machine
Maximum cutting capacity: 100 mm
Cutting disc specifications: φ350×2.5×32 (mm)
Spindle travel: 145 mm
Worktable travel: 300 mm
Worktable dimensions: 330 × 280 mm
Cutting chamber material: stainless steel
Automatic Metallographic Sample Cutting Machine
Maximum cutting capacity: Φ100 mm
Cutting disc specifications (mm): φ350×2.5×32 (mm)
Spindle travel: 145 mm
Worktable travel: 300 mm
Worktable dimensions: 330 × 280 mm
Cutting chamber material: stainless steel